Case Study

Pen Injector Design Study

Case Study Challenge Pen injector design was outside of specification limits for user push force. Several improvements to the design were being contemplated – e.g., lubricant-loaded plastics ROI was indeterminant KDPD Approach Created analytical kinetic model for the pen injector Verified the analytical model with customized test apparatus and a rigorous, systematic, test plan Testing …

Pen Injector Design Study Read More »

Wearable Pump Capability Study

FPrin Case Study 1 – Design Capability Challenge: Client was unsure of robustness and fundamental viability of novel wearable pump concept Some initial prototyping and testing yielded mixed results The anticipated multiple cycles of prototype / test / iterate needed to establish viability would be expensive and many relevant test configurations – e.g., extremes of …

Wearable Pump Capability Study Read More »

Low Pressure Dynamic Seal Design

Case Study Challenge 3D simulations are time consuming, and expensive to execute, and it is difficult to extract actionable outputs Complex barrel valve with demanding sealing and actuation requirements KDPD Approach Reconsider simulation environment and constraints Utilize 2D simulations and 2D sweep along full-length of perimeter 2D simulation for reduced computational burden and easy iteration …

Low Pressure Dynamic Seal Design Read More »

Wright Brothers Case Study

Wright Brothers

Case Study The Wright brothers took a systems engineering approach to something that, at least superficially, appeared to be relatively simple – after all birds, insects, and mammals were all doing it – and concluded that they needed to develop a systematic, bottom-up, sub-system based, solution to the challenge. Plenty of their peers – typically …

Wright Brothers Read More »

First Principles Test Apparatus Case Study

First Principles Test Apparatus

Case Study Challenge Client was not confident in the robustness of the clinical supplies – specifically motor-gearbox and batteries Because the design was locked, screening was the only viable way of ensuring capable clinical devices Clinical supply team needed a simple, first-principles based, method of characterizing motor-gearbox Our client was concerned about robustness of clinical …

First Principles Test Apparatus Read More »

Pressure Sensor And Occlusion Detection Case Study

Pressure Sensor and Occlusion Detection

Case Study Challenge System design required detection of tubing internal pressure indirectly across a membrane Inputs and outputs, interfaces and interactions were not well-defined or understood Fundamentals of the pressure to force transformation sensor were not well understood The development team did not have a good understanding of the terms in the transfer function between …

Pressure Sensor and Occlusion Detection Read More »

Low Pressure Dynamic Seal Design Case Study

Low Pressure Static Seal Design

Case Study Challenge Seal design with orthogonal requirements Passes leak specification while allowing relative motion between two plastic parts Seal design space is constrained by previous decision to incorporate O-Ring seal The client’s design requires an airtight seal interface which is also subjected to axial and rotational relative motion. This results in orthogonal requirements with …

Low Pressure Static Seal Design Read More »

Complex Applicator Case Study

Complex Applicator

Case Study Challenge Complex actuator with multiple springs and several frictional interfaces and latches defining distinct regions of travel Identify a small number of key success criteria to evaluate robustness Determine robustness of a single-use applicator for a wearable sensor prior to committing to expensive (time and $) tooling and large-scale builds and test We …

Complex Applicator Read More »